WCSE 2016
ISBN: 978-981-11-0008-6 DOI: 10.18178/wcse.2016.06.050

Implementation of Real Time Remote Water Quality Monitoring System Using Wireless Sensors and Arduino Based Data Logger

Goib Wiranto, Yudi Y. Maulana, Iqbal Syamsu, Dayat Kurniawan

Abstract— The design and implementation of a Wireless Sensor Network (WSN) for real time remote water quality monitoring system will be described in this paper. The main system consists of a wireless sensing node, an arduino based data logger with onsite display, and a web based data server. The wireless sensing node was used to collect information on the water quality parameters, that is DO, pH, and temperature, and send the measured parameter values to the data logger using Xbee wireless transmitter. Central to the system is the data logger, where data will be displayed and transmitted to the web based server using GPRS protocol. The system has been implemented to monitor the water quality parameters at a shrimp aquaculture in Bangka island, and data have been continuously collected by web server in Bandung, West Java for several months.

Index Terms— water quality; online monitoring; sensors; database server; data logger

Goib Wiranto, Yudi Y. Maulana, Iqbal Syamsu, Dayat Kurniawan
Research Center for Electronics and Telecommunication, Indonesian Institute of Sciences (LIPI), INDONESIA

[Download]


Cite: Goib Wiranto, Yudi Y. Maulana, Iqbal Syamsu, Dayat Kurniawan, "Implementation of Real Time Remote Water Quality Monitoring System Using Wireless Sensors and Arduino Based Data Logger," Proceedings of 2016 6th International Workshop on Computer Science and Engineering, pp. 325-329, Tokyo, 17-19 June, 2016.